[hermon] Minimise reset time
Check for reset completion by waiting for the device to respond to PCI configuration cycles, as documented in the Programmer's Reference Manual. On the original ConnectX HCA, this reduces the time spent on reset from 1000ms down to 1ms. Signed-off-by: Michael Brown <mcb30@ipxe.org>
This commit is contained in:
@@ -35,7 +35,7 @@ FILE_LICENCE ( GPL2_OR_LATER );
|
||||
/* Device reset */
|
||||
#define HERMON_RESET_OFFSET 0x0f0010
|
||||
#define HERMON_RESET_MAGIC 0x01000001UL
|
||||
#define HERMON_RESET_WAIT_TIME_MS 1000
|
||||
#define HERMON_RESET_MAX_WAIT_MS 1000
|
||||
|
||||
/* Work queue entry and completion queue entry opcodes */
|
||||
#define HERMON_OPCODE_NOP 0x00
|
||||
|
||||
Reference in New Issue