[hermon] Reset device during probe()
Some systems will retry their boot sequence in the event of a boot failure. On these systems, the second and subsequent boot attempts will fail to initialise the Hermon HCA. Fix by resetting the HCA during probe(). This incurs a one-second cost, but there seems to be no viable alternative. Originally-fixed-by: Itay Gazit <itaygazit@gmail.com>
This commit is contained in:
@@ -29,6 +29,11 @@ FILE_LICENCE ( GPL2_OR_LATER );
|
||||
#define HERMON_PCI_CONFIG_BAR_SIZE 0x100000
|
||||
#define HERMON_PCI_UAR_BAR PCI_BASE_ADDRESS_2
|
||||
|
||||
/* Device reset */
|
||||
#define HERMON_RESET_OFFSET 0x0f0010
|
||||
#define HERMON_RESET_MAGIC 0x01000000UL
|
||||
#define HERMON_RESET_WAIT_TIME_MS 1000
|
||||
|
||||
/* Work queue entry and completion queue entry opcodes */
|
||||
#define HERMON_OPCODE_NOP 0x00
|
||||
#define HERMON_OPCODE_SEND 0x0a
|
||||
|
||||
Reference in New Issue
Block a user